Monolithic integration of a smart temperature sensor on a modular silicon-based organ-on-a-chip device

Nikolas Gaio, Henk van Zeijl, Sten Vollebregt, Paul Dijkstra, Ronald Dekker, Wouter A. Serdijn, Vasiliki Giagka

Sensors and Actuators A Physical · 2020 · 37 citations · 16 references

DOIFull text

Open access

Concepts

TL;DR

Organ‑on‑a‑chip technology is used to study iPSC biology during drug screening, and commercial foundry CMOS processes could enable large‑scale, closed‑loop multi‑sensing integration in such devices. The study aims to construct OOCs equipped with highly compact in‑situ sensors that can accurately monitor, in real time, the extracellular fluid environment and anticipate vital physiological changes. We co‑fabricated a CMOS smart temperature sensor on the same substrate as a silicon‑based OOC, creating the first monolithically integrated in‑situ smart temperature‑sensing system on a micromachined silicon‑based OOC device. Wafer measurements show a temperature resolution better than ±0.2 °C, nonlinearity below 0.05 % over 30–40 °C, and a time response more than ten times faster than the convection‑cooling constant of a 0.4 ml PBS medium, marking the first step toward OOCs with seamless integrated CMOS sensors for real‑time multi‑parameter monitoring.

Abstract

One of the many applications of organ-on-a-chip (OOC) technology is the study of biological processes in human induced pluripotent stem cells (iPSCs) during pharmacological drug screening. It is of paramount importance to construct OOCs equipped with highly compact in situ sensors that can accurately monitor, in real time, the extracellular fluid environment and anticipate any vital physiological changes of the culture. In this paper, we report the co-fabrication of a CMOS smart sensor on the same substrate as our silicon-based OOC for real-time in situ temperature measurement of the cell culture. The proposed CMOS circuit is developed to provide the first monolithically integrated in situ smart temperature-sensing system on a micromachined silicon-based OOC device. Measurement results on wafer reveal a resolution of less than ±0.2 °C and a nonlinearity error of less than 0.05% across a temperature range from 30 to 40 °C. The sensor's time response is more than 10 times faster than the time constant of the convection-cooling mechanism found for a medium containing 0.4 ml of PBS solution. All in all, this work is the first step towards realizing OOCs with seamless integrated CMOS-based sensors capable to measure, in real time, multiple physical quantities found in cell culture experiments. It is expected that the use of commercial foundry CMOS processes may enable OOCs with very large scale of multi-sensing integration and actuation in a closed-loop system manner.

References

16