IEEE Transactions on Transportation Electrification · 2020 · 11 citations · 9 references
EngineeringElectrical EngineeringMicroelectronicsPower ElectronicsSemiconductor DevicesCondition MonitoringDevice ReliabilityFault DetectionPower System ReliabilityPulse-width ModulationSemiconductor ReliabilityDegradation MonitoringGate Oxide DegradationInverter Fault DiagnosisOnline Fault DetectionPower Device ReliabilityReliability Analysis Of Power ElectronicsSpace Vector ModulationSpace Vector Pulse-width Modulation
Failure in electrical machines or their drives can be catastrophic in safety-critical applications. Both silicon and silicon-carbide MOSFETs experience gate oxide degradation that leads to device failure. It is ideal to detect gate oxide degradation early using noninvasive, online techniques. In this article, an online gate oxide degradation detection method is proposed to reduce the reliability concern of using MOSFET switching devices. Gate oxide degradation causes a delay in phase current rise. Although the delay is short, it affects the voltage commands calculated in the controller. It is shown through analysis, simulation, and experiment that space vector pulsewidth modulation (SVPWM) duty cycle commands reflect the delay in phase current rise caused by gate oxide degradation.
9
Seungdeog Choi, Moinul Shahidul Haque, Md Tawhid Bin Tarek et al. · IEEE Transactions on Transportation Electrification · 2018 · 188 citations
Engineering, Electrical Engineering, Condition Assessment +16
Real-Time Aging Detection of SiC MOSFETs
Feyzullah Erturk, Enes Uğur, J.B. Olson et al. · IEEE Transactions on Industry Applications · 2018 · 79 citations