IEEE Journal of Biomedical and Health Informatics · 2020 · 31 citations · 31 references
EngineeringMechatronics EngineeringRobotics EngineeringPhysical TherapySensor FusionSensorsGait AnalysisGait AssessmentJoint Motion AnalysisMotion CaptureMotion SensorsRehabilitation RoboticsData FusionExtended Kalman FilterInertial Measurement Unit FusionInertial Measurement UnitsMotion SensingMultiplicative Extended Kalman FilterPhysical Therapy AssessmentPhysical Therapy Rehabilitation
The knee flexion-extension angle is an important variable to be monitored in various clinical scenarios, for example, during physical rehabilitation assessment. The purpose of this work is to develop and validate a sensor fusion system based on a knee sleeve for monitoring of physical therapy. The system consists of merging data from two inertial measurement units (IMUs) and an intensityvariation based Polymer Optical Fiber (POF) curvature sensor using a quaternion-based Multiplicative Extended Kalman Filter (MEKF). The proposed data fusion method is magnetometer-free and deals with sensors' uncertainties through reliability intervals defined during gait. Walking trials were performed by twelve healthy participants using our knee sleeve system and results were validated against a gold standard motion capture system. Additionally, a comparison with other three knee angle estimation methods, which are exclusively based on IMUs, was carried out. The proposed system presented better performance (mean RMSE <; 3.3°, LFM coefficients, α <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> = 0.99 ± 0.04, α <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> = 0.70 ± 2.29, R <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> = 0.98 ± 0.01 and ρC > 0.99) when compared to the other evaluated methods. Experimental results demonstrate the usability and feasibility of our system to estimate knee motion with high accuracy, repeatability, and reproducibility. This wearable system may be suitable for motion assessment in rehabilitation labs in future studies.
31
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
IMU-Based Joint Angle Measurement for Gait Analysis
Thomas Seel, Jörg Raisch, Thomas Schauer · Sensors · 2014 · 857 citations · Full text
Optical Sensors Based on Plastic Fibers
Lúcia Bilro, Nélia Alberto, João L. Pinto et al. · Sensors · 2012 · 344 citations · Full text