Development and analytical validation of a next-generation sequencing based microsatellite instability (MSI) assay

Sarabjot Pabla, Jonathan Andreas, Felicia L. Lenzo, Blake Burgher, Jacob Hagen, Vincent Giamo, Mary Nesline, Yirong Wang, Mark Gardner, Jeffrey M. Conroy,

Oncotarget · 2019 · 20 citations · 19 references

DOIFull text

Open access

Concepts

Abstract

// Sarabjot Pabla 1 , * , Jonathan Andreas 1 , * , Felicia L. Lenzo 1 , Blake Burgher 1 , Jacob Hagen 1 , Vincent Giamo 1 , Mary K. Nesline 1 , Yirong Wang 1 , Mark Gardner 1 , Jeffrey M. Conroy 1 , 2 , Antonios Papanicolau-Sengos 1 , Carl Morrison 1 , 2 and Sean T. Glenn 1 , 2 , 3 1 OmniSeq Inc., Buffalo, NY 14203, USA 2 Center for Personalized Medicine, Roswell Park Comprehensive Cancer Center, Buffalo, NY 14263, USA 3 Department of Molecular and Cellular Biology, Roswell Park Comprehensive Cancer Center, Buffalo, NY 14263, USA * These authors contributed equally to this work Correspondence to: Sean T. Glenn, email: sean.glenn@omniseq.com Keywords: next-generation sequencing; NGS; microsatellite instability; MSI Abbreviations: NGS: next-generation sequencing Received: June 10, 2019     Accepted: July 29, 2019     Published: August 27, 2019 ABSTRACT Background We have developed and analytically validated a next-generation sequencing (NGS) assay to classify microsatellite instability (MSI) in formalin-fixed paraffin-embedded (FFPE) tumor specimens. Methodology The assay relies on DNA-seq evaluation of insertion/deletion (indel) variability at 29 highly informative genomic loci to estimate MSI status without the requirement for matched-normal tissue. The assay has a clinically relevant five-day turnaround time and can be conducted on as little as 20 ng genomic DNA with a batch size of up to forty samples in a single run. Results The MSI detection method was developed on a training set ( n = 94) consisting of 22 MSI-H, 24 MSS, and 47 matched normal samples and tested on an independent test set of 24 MSI-H and 24 MSS specimens. Assay performance with respect to accuracy, reproducibility, precision as well as control sample performance was estimated across a wide range of FFPE samples of multiple histologies to address pre-analytical variability (percent tumor nuclei), and analytical variability (batch size, run, day, operator). Analytical precision studies demonstrated that the assay is highly reproducible and accurate as compared to established gold standard PCR methodology and has been validated through NYS CLEP. Significance This assay provides clinicians with robust and reproducible NGS-based MSI testing without the need of matched normal tissue to inform clinical decision making for patients with solid tumors.

References

19