IUCrJ · 2019 · 52 citations · 40 references
Natural SciencesMaterials ScienceOpticsRadiation DetectionRadiation MeasurementCrystallographyDetector TechnologyX-ray CrystallographyX-ray Data AnalysisX-ray DetectorsX-ray DiffractionCrystallographic Data ReductionDetector IntegrationDiffraction Data CollectionDiffraction Data ProcessingDiffraction PatternsSerial CrystallographySynchrotron CrystallographySynchrotron X-ray Crystallography
Reliable sample delivery and efficient use of limited beam time have remained bottlenecks for serial crystallography (SX). Using a high-intensity polychromatic X-ray beam in combination with a newly developed charge-integrating JUNGFRAU detector, we have applied the method of fixed-target SX to collect data at a rate of 1 kHz at a synchrotron-radiation facility. According to our data analysis for the given experimental conditions, only about 3 000 diffraction patterns are required for a high-quality diffraction dataset. With indexing rates of up to 25%, recording of such a dataset takes less than 30 s.
40
Features and development of <i>Coot</i>
Paul Emsley, Bernhard Lohkamp, W. G. Scott et al. · Acta Crystallographica Section D Biological Crystallography · 2010 · 29.6K citations · Full text
<i>Phaser</i>crystallographic software
Airlie J. McCoy, Ralf W. Grosse‐Kunstleve, Paul D. Adams et al. · Journal of Applied Crystallography · 2007 · 20.9K citations · Full text