IEEE Journal of Solid-State Circuits · 2019 · 52 citations · 25 references
EngineeringComputer EngineeringElectrical EngineeringMicroelectronicsSemiconductor DevicesSensorsCmos Circuit DesignDigital Integrated Circuit DesignDigital Integrated CircuitsTemperature MeasurementTemperature SensorsThermal SensorsAnalog-to-digital Converter IntegrationCmos Analog Integrated CircuitsComplementary Metal-oxide-semiconductor DevicesIntegrated Sensor DesignTemperature Sensor ControlTemperature Sensor InterfacingTime ConversionUltra-low-power Cmos
A sub-nW fully integrated temperature sensor is presented that digitizes temperature via a capacitive charging time feedback loop controlled by a least significant bit (LSB)-first algorithm. Specifically, an ultra-low-power current reference generator charges two metal-insulator-metal (MIM) capacitors C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">top</sub> and C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">bot</sub> , generating V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ramp,top</sub> and V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ramp,bot</sub> which are then compared to a constant with temperature (CWT) voltage and a proportional to absolute temperature (PTAT) voltage, respectively. Temperature is then digitized by matching the charging time between the V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ramp,top</sub> and V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ramp,bot</sub> via feedback tuning of C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">top</sub> driven by an energy-efficient digital processing unit (DPU) for direct ultra-low-power digital readout. The design is fabricated in 65 nm complementary metal-oxide-semiconductor, and measurement from 12 samples reveals a maximum temperature error of +1.61 °C/-1.53 °C (+0.86 °C/-0.83 °C) and +0.81 °C/-0.75 °C when operating from 0 °C to 100 °C after two-point (three-point) calibration without and with trimming, respectively. Operating from a 0.5 V supply, the 12 samples consumed an average power of 763 pW at 20 °C, which after a 0.3 s conversion time results in 230 pJ/conversion.
25
A cubic-millimeter energy-autonomous wireless intraocular pressure monitor
Gregory Chen, Hassan Ghaed, Razi Haque et al. · 2011 · 207 citations
Medicine, Ophthalmology, Surgery +14