Journal of Proteome Research · 2018 · 33 citations · 29 references
Life SciencesBiochemistryProtein BiochemistryProteomicsProteomics InformaticsBottom-up ProteomicsMass Spectrometry-based ProteomicsPeptide IdentificationProtein IdentificationProtein InferenceProtein QuantificationDatabase Search-based InferenceInference In Shotgun ProteomicsInference Under Peptide UncertaintyPeptide-protein InferencePeptide-to-protein InferenceProtein Content AnalysisProtein Inference AlgorithmsProtein Inference Benchmarking
A natural way to benchmark the performance of an analytical experimental setup is to use samples of known composition and see to what degree one can correctly infer the content of such a sample from the data. For shotgun proteomics, one of the inherent problems of interpreting data is that the measured analytes are peptides and not the actual proteins themselves. As some proteins share proteolytic peptides, there might be more than one possible causative set of proteins resulting in a given set of peptides and there is a need for mechanisms that infer proteins from lists of detected peptides. A weakness of commercially available samples of known content is that they consist of proteins that are deliberately selected for producing tryptic peptides that are unique to a single protein. Unfortunately, such samples do not expose any complications in protein inference. Hence, for a realistic benchmark of protein inference procedures, there is a need for samples of known content where the present proteins share peptides with known absent proteins. Here, we present such a standard, that is based on E. coli expressed human protein fragments. To illustrate the application of this standard, we benchmark a set of different protein inference procedures on the data. We observe that inference procedures excluding shared peptides provide more accurate estimates of errors compared to methods that include information from shared peptides, while still giving a reasonable performance in terms of the number of identified proteins. We also demonstrate that using a sample of known protein content without proteins with shared tryptic peptides can give a false sense of accuracy for many protein inference methods.
29
Universal sample preparation method for proteome analysis
Jacek R. Wiśniewski, Alexandre Zougman, Nagarjuna Nagaraj et al. · Nature Methods · 2009 · 8.7K citations
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Lukas Käll, Jesse D. Canterbury, Jason Weston et al. · Nature Methods · 2007 · 2.6K citations
ProteoWizard: open source software for rapid proteomics tools development
Darren Kessner, Matt Chambers, Robert Burke et al. · Bioinformatics · 2008 · 2.1K citations · Full text
Junmin Peng, Joshua E. Elias, Carson C. Thoreen et al. · Journal of Proteome Research · 2002 · 1.7K citations