IEEE Electron Device Letters · 2017 · 17 citations · 20 references
Natural SciencesMaterials EngineeringMaterials ScienceElectrochemistryElectronic MaterialsMaterials ChemistryChemical SensorsElectrochemical SensorsGas SensorsMetal OxidesSensor MaterialsSurface PhysicsCarrier ConcentrationGallium OxideGas Sensor SensitivityMetal Oxide CatalystsMetal Oxide Gas SensorsMetal Oxide Sensor MaterialsSensor SensitivityTransition Metal Oxides
To enhance the performance of semiconducting metal oxides, as hydrogen (H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) sensor, we introduced a high carrier concentration (N <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</sub> ) metal oxide, indium- gallium-zinc oxide (IGZO), combined with palladium (Pd) catalysis. This allowed the detection of low concentrations of H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> at room temperature. The base current level was linearly increased with the Pd thickness. As a result, a high sensor sensitivity of 6.1 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sup> % at 5% H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentration was obtained using a 1-nm-thick Pd-decorated IGZO film. Comparative studies with a zinc oxide (ZnO) counterpart showed that the Nd of IGZO (8 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">18</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup> ) is significantly higher than that of ZnO (2 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">16</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup> ), indicating a closer location for the Fermi level of IGZO to the conduction band. Therefore, a relatively small amount of electron-donating H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> was required to overcome the energy barrier in IGZO. Consequently, the 1-nm-thick Pd-decorated IGZO sensor responded to a gas level as low as 0.01% (100 ppm) and demonstrated a 70-fold higher sensitivity compared with ZnO sensor at all H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentrations.
20
Hydrogen sensor based on graphene/ZnO nanocomposite
Kanika Anand, Onkar Singh, Manmeet Pal Singh et al. · Sensors and Actuators B Chemical · 2014 · 315 citations
Hydrogen gas sensor based on metal oxide nanoparticles decorated graphene transistor
Zhangyuan Zhang, Xuming Zou, Lei Xu et al. · Nanoscale · 2015 · 209 citations