Frontiers in Immunology · 2017 · 19 citations · 20 references
Life SciencesCell BiologyImmunologyCellular ImmunologyClinical ImmunologyMolecular ImmunologyCell CharacterizationHistocompatibilityHuman Leukocyte Antigen SystemMajor Histocompatibility ComplexRare Cell Population DetectionT Cell BiologyAntigen Presenting CellsAutomated Data AnalysisFlow Cytometric Immune PhenotypingFlow Cytometric ImmunophenotypingFlow Cytometry ImmunophenotypingGatingTechnical Variation AnalysisTechnical Variation Correction
Manual analysis of flow cytometry data and subjective gate-border decisions taken by individuals continue to be a source of variation in the assessment of antigen-specific T cells when comparing data across laboratories, and also over time in individual labs. Therefore, strategies to provide automated analysis of MHC multimer-binding T cells represent an attractive solution to decrease subjectivity and technical variation. The challenge of using an automated analysis approach is that MHC multimer-binding T cell populations are often rare and therefore difficult to detect. We used a highly heterogeneous dataset from a recent MHC multimer proficiency panel to assess if MHC multimer-binding CD8+ T cells could be analyzed with computational solutions currently available, and if such analyses would reduce the technical variation across different laboratories. We used three different methods, FLOCK, SWIFT, and ReFlow to analyze flow cytometry data files from 28 laboratories. Each laboratory screened for antigen-responsive T cell populations with frequency ranging from 0.01-1.5% of lymphocytes within samples from two donors. Experience from this analysis shows that all three programs can be used for the identification of high to intermediate frequency of MHC multimer-binding T cell populations, with results very similar to that of manual gating. For the less frequent populations (<0.1% of live, single lymphocytes), SWIFT outperformed the other tools. As used in this study, none of the algorithms offered a completely automated pipeline for identification of MHC multimer populations, as varying degrees of human interventions were needed to complete the analysis. In this study, we demonstrate the feasibility of using automated analysis pipelines for assessing and identifying even rare populations of antigen responsive T cells and discuss the main properties, differences and advantages of the different methods tested.
20
Phenotypic Analysis of Antigen-Specific T Lymphocytes
John D. Altman, Paul Moss, Philip Goulder et al. · Science · 1996 · 3.6K citations
Critical assessment of automated flow cytometry data analysis techniques
Nima Aghaeepour, Greg Finak, Holger H. Hoos et al. · Nature Methods · 2013 · 622 citations · Full text
Phenotypic analysis of antigen-specific T lymphocytes. Science. 1996. 274: 94-96.
John D. Altman, Paul Moss, Dan H. Barouch et al. · PubMed · 2011 · 573 citations
Design and use of conditional MHC class I ligands
Mireille Toebes, Miriam Coccoris, Adriaan D. Bins et al. · Nature Medicine · 2006 · 352 citations