IEEE Transactions on Industrial Electronics · 2017 · 41 citations · 36 references
EngineeringElectrical EngineeringAnalog ElectronicsPower ElectronicsQuality ControlControl SystemsControl TheoryImpedance ControlPower QualityRobust ControlVoltage RegulationHarmonic DistortionHarmonic MitigationHarmonic ReductionOutput ImpedanceOutput Impedance ControlTotal Harmonic DistortionTotal Harmonic Distortion ReductionVoltage
In this paper, a method to directly shape the output impedance of an inverter is proposed to reduce the total harmonic distortion of the output voltage, based on the uncertainty and disturbance estimator (UDE)-based robust control framework. It is shown that, because of the two-degree-of-freedom feature of the UDE-based control strategy, the UDE filter directly affects the inverter output impedance. A multi-band-stop filter instead of a commonly adopted low-pass filter is then proposed to directly minimize the output impedance around the harmonics to reduce the effect of nonlinear loads and assure robustness to frequency variations. Two tradeoffs are revealed: one between filter bandwidth and stability and the other between robustness and the number of harmonics suppressed. The effectiveness of the proposed control strategy is fully supported by experimental results.
36
Disturbance-Observer-Based Control and Related Methods—An Overview
Wen‐Hua Chen, Jun Yang, Lei Guo et al. · IEEE Transactions on Industrial Electronics · 2015 · 2.8K citations · Full text
Josep M. Guerrero, J. Matas, Luis García de Vicuña et al. · IEEE Transactions on Industrial Electronics · 2007 · 1.1K citations
Engineering, Electrical Engineering, Distributed Systems +16