IEEE Transactions on Components Packaging and Manufacturing Technology · 2016 · 29 citations · 9 references
EngineeringElectrical EngineeringMechanical EngineeringHeat TransferThermal AnalysisThermodynamicsHeat ConductionHeat Transfer AnalysisHeat Transfer ModelingTemperature MeasurementThermal DesignThermal SimulationContact Temperature MeasurementElectro-thermal ModelingHeat DissipationHigh-voltage Power SystemsTemperature Rise AnalysisThermal Performance MetricsVoltage Drop AnalysisVoltage Drop Calculations
Researchers and engineers use the voltage–temperature ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$V$ </tex-math></inline-formula> – <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$T$ </tex-math></inline-formula> ) relation to calculate the maximum temperature of electric contacts from contact voltage drop and thus evaluate their performance. However, researchers found deviations from the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$V$ </tex-math></inline-formula> – <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$T$ </tex-math></inline-formula> relation for large contact systems when heat dissipation to the environment becomes significant. We investigated the applicability of the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$V$ </tex-math></inline-formula> – <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$T$ </tex-math></inline-formula> relation to high-power contact systems with spring-loaded contact elements. Such connections with rated normal currents of several kiloamperes and short-time withstand currents of several tens of kiloamperes are used in high-voltage switchgear. We loaded a connector cooled by a potent variable water cooling system with continuous ac up to 6.7 kA to create a multitude of thermally symmetric and asymmetric steady-state operating points. However, temperature differences in the contact system remained below 20 K. Temperature differences calculated with the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$V$ </tex-math></inline-formula> – <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$T$ </tex-math></inline-formula> relation were 23% higher than the measured values, but nevertheless deliver an assessment of the maximum contact system temperature valid for engineering purposes. In the case of a 1-s, 20-kA short-circuit current, a transient temperature rise occurs in the contact system. We numerically calculated the development of the spatial temperature distribution over time and found significant differences to the electric–thermal steady state. While contacts react very quickly and even oscillate with twice the line frequency on ac load, the contact element and conductor continuously heat up and do not reach the steady state.
9
Thermo-mechanical study of a power connector
Erwann Carvou, R. El Abdi, J. Razafiarivelo et al. · Measurement · 2012 · 39 citations