PLoS ONE · 2016 · 63 citations · 27 references
Life SciencesInfectious DiseasesMicrobiologyBacteriologyDialysisHemodialysisBacterial BiofilmsBiofilm FormationBiofilm Formation In InfectionMicrobial BiofilmsMicrobiological AnalysisPeritoneal DialysisBiofilm Formation AssaysBiofilm-associated InfectionsCatheter-associated BiofilmsCoagulase-negative StaphylococciMicrobial Biofilm PathogenesisPeritoneal Dialysis CarePeritoneal Dialysis ComplicationsStaphylococcus Aureus Contamination
Infections are major complications in peritoneal dialysis (PD) with a multifactorial etiology that comprises patient, microbial and dialytic factors. This study aimed at investigating the contribution of microbial biofilms on PD catheters to recalcitrant infections and their interplay with PD related-factors. A prospective observational study was performed on 47 patients attending Centro Hospitalar of Porto and Vila Nova de Gaia/Espinho to whom the catheter was removed due to infectious (n = 16) and non-infectious causes (n = 31). Microbial density on the catheter was assessed by culture methods and the isolated microorganisms identified by matrix-assisted laser desorption/ionization time-of-flight intact cell mass spectrometry. The effect of conventional and three biocompatible PD solutions on 16 Coagulase Negative Staphylococci (CNS) and 10 Pseudomonas aeruginosa strains planktonic growth and biofilm formation was evaluated. Cultures were positive in 87.5% of the catheters removed due infectious and 90.3% removed due to non-infectious causes. However, microbial yields were higher on the cuffs of catheters removed due to infection vs. non-infection. Staphylococci (CNS and Staphylococcus aureus) and P. aeruginosa were the predominant species: 32% and 20% in the infection and 43.3% and 22.7% in the non-infection group, respectively. In general, PD solutions had a detrimental effect on planktonic CNS and P. aeruginosa strains growth. All strains formed biofilms in the presence of PD solutions. The solutions had a more detrimental effect on P. aeruginosa than CNS strains. No major differences were observed between conventional and biocompatible solutions, although in icodextrin solution biofilm biomass was lower than in bicarbonate/lactate solution. Overall, we show that microbial biofilm is universal in PD catheters with the subclinical menace of Staphylococci and P. aeruginosa. Cuffs colonization may significantly contribute to infection. PD solutions differentially impact microbial species. This knowledge is important for the development of infection diagnosis, treatment and preventive strategies.
27
World Medical Association Declaration of Helsinki
JAMA · 2013 · 29.4K citations
An Information-Intensive Approach to the Molecular Pharmacology of Cancer
John N. Weinstein, Timothy G. Myers, P M O'Connor et al. · Science · 1997 · 1.2K citations
Medicine, Oncology, Pharmacology +14
Peritoneal Dialysis-Related Infections Recommendations: 2010 Update
Philip Kam‐Tao Li, Cheuk‐Chun Szeto, Beth Piraino et al. · Peritoneal Dialysis International · 2010 · 895 citations · Full text