Monitoring of a Hot Melt Coating Process via a Novel Multipoint Near-Infrared Spectrometer

Roland Hohl, Otto Scheibelhofer, Elena Stocker, Sharareh Salar Behzadi, Detlev Haack, Kai Koch, Peter Kerschhaggl, Dirk Lochmann, Stephan Sacher, Andreas Zimmer

AAPS PharmSciTech · 2016 · 11 citations · 24 references

DOIFull text

Open access

Concepts

Abstract

The aim of the present work was to develop a PAT strategy for the supervision of hot melt coating processes. Optical fibers were placed at various positions in the process chamber of a fluid bed device. Experiments were performed to determine the most suitable position for in-line process monitoring, taking into account such requirements as a good signal to noise ratio, the mitigation of dead zones, the ability to monitor the product over the entire process, and reproducibility. The experimental evidence suggested that the position at medium fluid bed height, looking towards the center, i.e., normal to particle movement, proved to be the most reliable position. In this study, the advantages of multipoint monitoring are shown, and an in-line-implementation was created. This enabled the real-time supervision of the process, including the fast detection of inhomogeneities and disturbances in the process chamber, and the compensation of sensor malfunction. In addition, a model for estimating the particle size distribution via NIR was successfully created. This ensures that the quality of the product and the endpoint of the coating process can be determined correctly.