Ozone Science and Engineering · 1994 · 25 citations · 11 references
Life SciencesMicrobiologyEnvironmental ChemistryEnvironmental RemediationWater TreatmentEgg DisinfectionOzone ChemistryReactive Oxygen SpeciesBicarbonate Buffer SystemDisinfectionHydrogen Peroxide DisinfectionOzoneOzone DecompositionOzone SanitizationPhosphate Buffer SystemRadical Species
Abstract The disinfection effects of the ozone molecule alone and that of ozone decomposition products when inactivating Giardia muris cysts were investigated at bench-scale using two different ozone demand-free laboratory buffer systems. The first water was a 0.05 M phosphate buffer with hydrogen peroxide added at a 10:1 weight ratio. The second water was a 0.05 M phosphate – 0.01 M bicarbonate buffer which quickly scavenged radical species from ozone decomposition. The C3H/HeN mouse model was used to assess the infectivity of ozone treated cysts. The phosphate-bicarbonate buffer system had significantly greater (P ≤ 0.05) inactivation of G. muris cysts than that observed in the phosphate buffer – peroxide system where ozone was completely decomposed in less than 120 s. Consequently, the design of ozone disinfection processes should maintain ozone residual for disinfection prior to the addition of hydrogen peroxide for the oxidation of other compounds.
11
Giardiasis in the Mouse: An Animal Model
Ian C. Roberts‐Thomson, David Stevens, Adel A. F. Mahmoud et al. · Gastroenterology · 1976 · 325 citations
Charles W. Labatiuk, Frank W. Schaefer, Gordon R. Finch et al. · Applied and Environmental Microbiology · 1991 · 47 citations · Full text