A detailed IC package numerical model calibration methodology

Robin Bornoff, András Vass-Várnai

2013 · 24 citations · 7 references

Concepts

Abstract

Experimentally derived structure functions can be used to provide insights into the thermal resistances and capacitances heat experiences as it travels from a die through and beyond an IC package. A 3D “detailed” numerical model of the package that purports to explicitly represent the internal construction of the package requires material properties and geometric sizes to be accurately specified. A structure function derived from simulating the detailed numerical model can itself be compared to the experimentally derived reference example. Deviations between experimental and numerical SFs indicate error sites within the detailed model and an indication of whether the thermal resistances or thermal capacitances of the numerical would need to be increased or decreased to match the experimentally observed values. Iterative modifications of the detailed model, based on successive structure function comparisons, will achieve a fully calibrated detailed numerical package model.

References

7