Amperometric Determination of Sulfide by Glassy Carbon Electrode Modified with Hemin Functionalized Reduced Graphene Oxide

Xiaodong Cao, Jiaona Gao, Yingwang Ye, Yingwang Ye, Pengfei Wang, Shun Ding, Hanju Sun

Electroanalysis · 2015 · 14 citations · 23 references

Concepts

Abstract

Abstract This work describes a new approach for rapid detection of sulfide using a glassy carbon electrode (GCE) modified with hemin functionalized reduced graphene oxide (hemin‐rGO). The modified GCE was applied to the selective amperometric detection of sulfide at a working potential of 0.05 V (vs. Ag/AgCl) at pH 7.5, which gave a linear range of 0.002–0.212 mM, a sensitivity of 246.5 µA mM −1 cm −2 , and a detection limit of 1.3 µM. The proposed method was applied in determination of sulfide‐spiked water, and the method was verified with recovery percentage of standard samples with an acceptable satisfaction.

References

23