Optical and thermal performance advantages for silicon substrates in YBCO bolometer devices

D. B. Fenner, Q. Li, W.D. Hamblen, M.E. Johansson, D.G. Hamblen, L. Lynds, J. I. Budnick

IEEE Transactions on Applied Superconductivity · 1993 · 17 citations · 7 references

Concepts

Abstract

The authors review recent progress they have made in the fabrication of epitaxial YBCO thin-film bolometers (photothermal infrared detectors) on Si wafers. Infrared (IR) transmission of the Si substrates, yttria-stabilized zirconia (YSZ) buffer layers on Si, and YBCO/YSZ/Si has ben measured from the near to the far IR at low temperatures. Si is shown to be much superior to other available choices of substrate for epitaxial-YBCO film bolometers. It is also shown, by various wafer fabrications, that the high strength and thermal conductivity of Si can be exploited to considerably reduce the device thermal-equilibration time, when irradiated with weak IR pulses, and concomitantly increase the device sensitivity. Further, the authors have fabricated monolithic quad arrays of bolometers, and found excellent element-to-element uniformity in their transitions and in their function as detectors for Fourier-transform IR spectroscopy. They have also fabricated an epitaxial YBCO-film bolometer on a submicron-thick window in a Si wafer. The rise and fall times (10-90%) were less than 500 mu s, under chopped IR illumination.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>