Total Dose Radiation Response of Nitrided and Non-nitrided SiO$_{2}$/4H-SiC MOS Capacitors

S. K. Dixit, Sarit Dhar, John Rozen, Sanwu Wang, Ronald D. Schrimpf, Daniel M. Fleetwood, Sokrates T. Pantelides, John R. Williams, L. C. Feldman

IEEE Transactions on Nuclear Science · 2006 · 56 citations · 35 references

Concepts

Abstract

The total dose radiation response of nitrided and non-nitrided n-type 4H-SiC is reported for metal oxide semiconductor capacitors exposed to 10-keV X-rays under positive bias. The radiation response is affected strongly by differences in the SiC band gap and interface/near interface SiO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> trap density from typical Si MOS devices. Significantly higher net trapped positive charge densities were observed in nitrided n-SiC MOS capacitors compared to the non-nitrided samples. The mechanisms contributing to the differences in the charge trapping in these devices are discussed. Differences in the interfacial layer between SiO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> /Si and SiO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> /SiC are responsible for the observed dissimilarities in charge trapping behavior

References

35