Sensors · 2007 · 61 citations · 59 references
MedicinePharmacologyToxicologyBiochemical PharmacologyElectroanalytical MethodsExperimental PharmacologyBioanalytical Method ValidationCytochrome P450 EnzymesCytochrome P450-mediated MetabolismMolecular Mechanisms Of ToxicityAh Receptor-mediated InductionCarbon Paste ElectrodesCytochrome P450 Enzyme ActivityFlavonoid GlycosidesFlavonoid MetabolismSquare-wave VoltammetryVoltammetry
About biological affecting of flavonoids on animal organisms is known less,thus we selected flavonoids, flavanones and flavones, and their glycosides, which wereexamined as potential inducers of cytochrome(s) P450 when administrated by gavages intoexperimental male rats. The study was focused on induction of CYP1A1, the majorcytochrome P450 involved in carcinogen activation. The data obtained demonstrate thenecessity of taking into account not only ability of flavonoids to bind to Ah receptor(induction factor) but also to concentrate on their distribution and metabolism (includingcolon microflora) in the body. After that we examined certain flavonoids as potential inducers of cytochrome P450, we wanted to suggest and optimize suitable electrochemical technique for determination of selected flavonoids (quercetin, quercitrin, rutin, chrysin and diosmin) in body liquids. For these purposes, we selected square wave voltannetry using carbon paste electrode. Primarily we aimed on investigation of their basic electrochemical behaviour. After that we have optimized frequency, step potential and supporting electrolyte. Based on the results obtained, we selected the most suitable conditions for determination of the flavonoids as follows: frequency 180 Hz, step potential 1.95 mV/s and phosphate buffer of pH 7 as supporting electrolyte. Detection limits (3 S/N) of the flavonoids were from units to tens of nM except diosmin, where the limit were higher than μM. In addition, we attempted to suggest a sensor for analysis of flavonoids in urine. It clearly follows from the results obtained that flavonoids can be analysed in the presence of animal urine, because urine did not influence much the signals of flavonoids (recoveries of the signals were about 90 %).
59
The Carbon Monoxide-binding Pigment of Liver Microsomes
Tsuneo Omura, Ryo Sato · Journal of Biological Chemistry · 1964 · 11.8K citations · Full text
Extraction and analysis of phenolics in food
M. Naczk, Fereidoon Shahidi · Journal of Chromatography A · 2004 · 1.3K citations
Extraction and analysis of phenolics in food
M. Naczk, Fereidoon Shahidi · Journal of Chromatography A · 2004 · 1.3K citations
Slobodan V. Jovanović, Steen Steenken, Mihajlo Tošić et al. · Journal of the American Chemical Society · 1994 · 1.2K citations