Journal of Microelectromechanical Systems · 2002 · 148 citations · 13 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsMicroelectromechanical SystemsMicrofabricationElectrode MaterialsMicrofabrication MaterialsMicrofabrication ProcessesBumpsElectrode FabricationElectrohydrodynamic FlowFluid-thermal CouplingMicropumpsPumpingReactive Ion EtchingStatic Pressure
This study designs, fabricates, and tests a novel electrohydrodynamic ion‑drag micropump that incorporates 3‑D triangular solder bumps on the electrodes to maximize electric field gradients. The pump was fabricated by sputter‑depositing niobium on a ceramic substrate, patterning with photoresist and reactive ion etching, then dipping into molten solder to create 3‑D triangular bumps; the resulting 19 mm × 32 mm × 1.05 mm device was produced in four variants and evaluated with static pressure tests using 3 M Thermal Fluid (HFE‑7100). Testing with HFE‑7100 showed a maximum pumping head of 700 Pa at 300 V, and the 3‑D bump structures, especially a saw‑tooth emitter, markedly improved performance.
This paper presents the design, fabrication, and testing of a novel electrohydrodynamic (EHD) ion-drag micropump. In order to maximize the electrical field gradients that are responsible for EHD pumping, we incorporated three-dimensional (3-D) triangular bumps of solder as part of the EHD electrodes. To form these bumps, Niobium was sputter-deposited onto a ceramic substrate, coated with photoresist, optically exposed and etched using a reactive ion etcher to define the electrode pattern. The substrate was then "dipped" into a molten solder pool. Since the solder adheres only to the metallic film, bumps of solder form on the electrodes, giving the electrodes a significant 3-D character. The overall dimensions of the micropump are 19 mm /spl times/ 32 mm /spl times/ 1.05 mm. Four different designs were fabricated and tested. Static pressure tests were performed with a 3M Thermal Fluid (HFE-7100) as the working fluid and the optimum design was identified. The results with the thermal fluid were highly promising and indicated a pumping head of up to 700 Pa at an applied voltage of 300 V. The experimental results for the four different designs show that the presence of the 3-D bump structures significantly improves the pumping performance. Also, a much better pumping performance was obtained with the micropump in which the emitter had a saw-tooth shape.
13
Otmar M. Stuetzer · Journal of Applied Physics · 1959 · 293 citations
Microfabricated electrohydrodynamic pumps
Stephen F. Bart, Lee S. Tavrow, Mehran Mehregany et al. · Sensors and Actuators A Physical · 1990 · 195 citations
William F. Pickard · Journal of Applied Physics · 1963 · 134 citations