IEEE Transactions on Industrial Electronics · 1992 · 61 citations · 6 references
EngineeringElectrical EngineeringBridge EngineeringCircuit TheoryPower ElectronicsAc-dc ConversionAc-dc ConvertersDc-dc ConversionDc-dc ConvertersPower QualityThree-phase CircuitsBridge RectifiersCurrent Harmonic DistortionCurrentsDiode Bridge RectifiersHarmonic ReductionNeutral PointThird Harmonic InjectionThree-phase Rectifiers
A novel method for reducing harmonic currents on the AC supply side of a three-phase bridge rectifier is presented. The principle of the method is to modify the current waveforms in the DC windings of the converter transformer by injecting a third harmonic current into the neutral point of the transformer. Passive LC filters connected between the rectifier output and the secondary neutral point act as third harmonic current sources. The effectiveness of the method is confirmed by laboratory recordings.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6