BMC Infectious Diseases · 2003 · 117 citations · 9 references
Life SciencesMicrobiologyBacteriologyMedical MicrobiologyWater TreatmentEnvironmental DisinfectionHigh-level DisinfectionMicrobial ContaminationMicrobial QualitySterilization TechniquesChemical Cleaning AgentsChemical DisinfectionChlorine-based DisinfectantsDisinfectionDisinfection KineticsEscherichia ColiGrowth In Defined MediaSanitization Kinetics
BACKGROUND: Prior to the selection of disinfectants for low, intermediate and high (sterilizing) levels, the decimal reduction time, D-value, for the most common and persistent bacteria identified at a health care facility should be determined. METHODS: The D-value was determined by inoculating 100 mL of disinfecting solution with 1 mL of a bacterial suspension (10(4)-10(5) CFU/mL for vegetative and spore forms). At regular intervals, 1 mL aliquots of this mixture were transferred to 8 mL of growth media containing a neutralizing agent, and incubated at optimal conditions for the microorganism. RESULTS: The highest D-values for various bacteria were determined for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0)--E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min) and 0.1% for B. stearothermophilus (D = 3.5 min) and B. subtilis (D = 3.2 min); (iii) 2.0% glutaraldehyde (pH 7.4)--B. stearothermophilus, B. subtilis (D = 25 min) and E. coli (D = 7.1 min); (iv) 0.5% formaldehyde (pH 6.5)--B. subtilis (D = 11.8 min), B. stearothermophilus (D = 10.9 min) and A. calcoaceticus (D = 5.2 min); (v) 2.0% chlorhexidine (pH 6.2)--B. stearothermophilus (D = 9.1 min), and at 0.4% for E. cloacae (D = 8.3 min); (vi) 1.0% Minncare (peracetic acid and hydrogen peroxide, pH 2.3)--B. stearothermophilus (D = 9.1 min) and E. coli (D = 6.7 min). CONCLUSIONS: The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations showed that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasizes the importance and need to develop routine and novel programs to evaluate product utility.
9
Disinfection, Sterilization and Preservation
Melina Le Duc · AORN Journal · 1969 · 674 citations
Disinfection, Sterilization, and Preservation.
D. A. Barnum · Europe PMC (PubMed Central) · 1970 · 121 citations