EngineeringBiomedical EngineeringPhysicsAcousticsSensorsUltrasoundAcoustic SensingAcoustic SensorsCavitationTransducer TechnologyUltrasonicsUltrasound InstrumentationAcoustic CavitationAcoustic Emission SensorsAcoustic PropertiesBandwidthPiezoelectric Acoustic SensorsUltrasonic SensingUltrasonic SensorsUltrasonic Transducers
The study introduces a novel ultrasonic cavitation sensor concept for monitoring microbubble acoustic emissions, detailing its design rationale, construction, and shield development. The sensor is a 32 mm high, 38 mm diameter right circular cylinder with a 30 mm internal diameter, lined with a 110‑µm piezoelectric film capable of detecting up to >10 MHz emissions, and is protected by a 4‑mm polyurethane shield that attenuates megahertz ultrasound while minimally affecting the 40 kHz field.
This paper describes a new concept for an ultrasonic cavitation sensor designed specifically for monitoring acoustic emissions generated by small microbubbles when driven by an applied acoustic field. Its novel features include a hollow, open-ended, cylindrical shape, with the sensor being a right circular cylinder of height 32 mm and external diameter 38 mm. The internal diameter of the sensor is 30 mm; its inner surface is fabricated from a 110-microm layer of piezoelectrically active film whose measurement bandwidth is sufficient to enable acoustic emissions up to and beyond 10 MHz to be monitored. When in use, the sensor is immersed within the liquid test medium and high frequency (megahertz) acoustic emissions occurring within the hollow body of the sensor are monitored. In order to shield the sensor response from events occurring outside the cylinder, the outer surface of the sensor cylinder is encapsulated within a special 4-mm thick polyurethane-based cavitation shield with acoustic properties specifically developed to be minimally perturbing to the 40 kHz applied acoustic field but attenuating to ultrasound generated at megahertz frequencies (plane-wave transmission loss > 30 dB at 1 MHz). This paper introduces the rationale behind the new sensor, describing details of its construction and the materials formulation program undertaken to develop the cavitation shield.
12
E.A. Neppiras · Physics Reports · 1980 · 761 citations
Cavitation produced by Ultrasonics
B E Noltingk, E.A. Neppiras · Proceedings of the Physical Society Section B · 1950 · 653 citations
Natural Sciences, Physics, Acoustics +16
Methods of experimental physics
A.F. Purdie · Optics & Laser Technology · 1980 · 130 citations
High-intensity ultrasonic fields
E.A. Neppiras · Ultrasonics · 1972 · 83 citations