IEEE Transactions on Industrial Electronics · 2008 · 313 citations · 6 references
EngineeringElectrical EngineeringPower ElectronicsPowertrain EngineeringProcess ControlDc-ac InvertersDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesModel Predictive ControlDirect Torque ControlHysteresisInduction Motor DrivesInverter SystemsMotor Drive ControlThree-phase Induction MachinesThree-phase Induction MotorsThree-phase Motor Drives
This paper describes the implementation of the model predictive direct torque control (MPDTC) algorithm for the control of three-phase induction motor drives comprising a three-level DC-link inverter. The MPDTC scheme is designed to keep the motor torque and stator flux and the inverter's neutral point potential within given hysteresis bounds while reducing the average switching frequency of the inverter, in comparison with the standard direct torque control (DTC) method. The algorithm is embedded in the control software environment of ABB's ACS6000 medium-voltage drive, and experimental results are provided which verify the advantageous features of MPDTC in terms of average inverter switching frequency reduction. More specifically, compared to standard DTC, the proposed MPDTC scheme achieves an average (over the whole operating range) reduction of the inverter switching frequency of 16.5%, but for specific operating conditions the reduction is as much as 37.4%.
6
A FPGA implementation of model predictive control
Keck Voon Ling, S.P. Yue, J.M. Maciejowski · 2006 · 128 citations