IEEE Transactions on Nuclear Science · 2001 · 68 citations · 8 references
EngineeringElectrical EngineeringMaterials ScienceRadiation DetectionSemiconductor DevicesSemiconductor MaterialsGamma-ray DetectionRadiation DetectorsSemiconductor DetectorsX-ray DetectionX-ray DetectorsX-ray SpectroscopyCurrent DensityDetector FabricationSchottky BarriersSchottky ContactsSilicon CarbideSilicon Carbide (Sic) MaterialsSilicon Semiconductor Detectors
We present the first experimental results of X-ray detection and spectroscopy by means of Schottky junctions on epitaxial silicon carbide (SiC). The devices have a junction area of 3 mm/sup 2/ on an n-type 4H-SiC layer 30 /spl mu/m thick with a dopant concentration of 1.8/spl times/10 cm at 300 K, the reverse current density of the best device varies between 2 pA/cm/sup 2/ and 18 pA/cm/sup 2/ as the mean electric field is increased from 40 kV/cm up to 170 kV/cm. The devices have been tested with X and /spl gamma/ rays from /sup 241/Am; the best measured energy resolution is 2.7 keV FWHM at room temperature.
8
Development of a silicon carbide radiation detector
F.H. Ruddy, A.R. Dulloo, J.G. Seidel et al. · IEEE Transactions on Nuclear Science · 1998 · 151 citations
Engineering, Electrical Engineering, Nuclear Engineering +17