jpa · 1995 · 13 citations · 10 references
AgricultureAgronomyCrop SciencesCrop ModelingCrop ProductionPlant NutritionAgronomic Performance EvaluationAgronomic Trait EvaluationNutritional Trait AssessmentProtein AnalysisQuality Trait EvaluationAgronomic CharacterizationCrop Quality AssessmentCrude Protein AccumulationCrude Protein AssessmentCrude Protein LevelDry Matter ContentNeutral Detergent FiberStem Cuttings
Predictive equations for alfalfa quality (PEAQ) based on the tallest stem and the most mature stem of a sample were developed to estimate the neutral detergent fiber (NDF), acid detergent fiber (ADF), and crude protein (CP) concentrations in alfalfa ( Medicago saliva L.). The objective of this study was to evaluate these equations in a preharvest setting in the field. Separate equations were developed for use on samples obtained from (i) all cuttings (original equations), (ii) first cutting only, and (iii) second and third cuttings only. Prediction equations accurately estimated alfalfa fiber composition of 308 samples taken in 1992 and 1993. Crude protein was not accurately predicted using PEAQ. Using the original PEAQ on all samples resulted in rz values of 0.72 for NDF and ADF and 0.37 for CP while root mean square error (RMSE) values were 3.02, 2.47, and 2.12% of dry matter (DM) for NDF, ADF, and CP, respectively. The relationship between PEAQ estimates and observed values did not improve using the first cut equations on first cut samples when compared with estimates obtained using the original equations on first cut samples. Equations developed from second and third cuts and the original equations predicted NDF and ADF similarly in second and third cut alfalfa. A nearly perfect relationship between predicted and observed values would be shown by a slope of 1.0 and a y‐intercept of 0.0. Twelve of the 15 equations had slopes statistically different from 1.0 and y‐intercepts different from 0.0 indicating bias in these models. The biological differences may be insignificant, however, since many of the values for slope and y‐intercept are relatively close to 1.0 and 0.0, respectively. Quality estimates were obtained for all samples using commercial near infrared reflectance spectroscopy (NIRS). Root mean square error and r 2 were similar for NDF and ADF using either PEAQ or NIRS. Near infrared reflectance spectroscopy was much more accurate than PEAQ in estimating CP. However, all NIRS regression equations were biased to some extent because slopes were different from 1.0 and y‐intercepts were different from 0.0. For field evaluations, the PEAQ method shows promise as a rapid and inexpensive method of estimating preharvest alfalfa fiber quality components, but not crude protein. Research Question Knowledge of alfalfa nutritive value is essential for making informed forage management decisions in alfalfa‐based livestock production systems. However, most harvest management and storage decisions are made with no chemical composition information because obtaining analytical data is time consuming and expensive. Equations developed at the University of Wisconsin may provide producers with a quick and inexpensive means of estimating alfalfa quality in the field before harvest. The purpose of this study was to evaluate these equations in a field setting using alfalfa samples gathered from several areas in Wisconsin throughout the growing season. Literature Summary The detergent fiber system of forage analysis (acid detergent fiber, ADF; and neutral detergent fiber, NDF) coupled with a measure of crude protein (CP) provide key information for balancing rations of lactating dairy cows. Standard lab analyses for NDF, ADF, and CP are available from six commercial labs in Wisconsin at costs of $15 to $22. With shipping time included, turnaround for results on a forage sample may range from 5 to 10 d. Most commercial labs now also estimate NDF, ADF, and CP by near infrared reflectance spectroscopy (NIRS) resulting in a lower cost per sample (from $8 to $10) and a shorter turnaround time (2 to 7 d including shipping). Neither standard lab analysis nor NIRS provide results quickly or economically enough to be used routinely as preharvest management aids. Predictive equations for alfalfa quality (PEAQ) would allow farmers to estimate preharvest alfalfa fiber quality components rapidly (1–5 min/sample) and inexpensively (a ruler, calculator, and time are the only requirements). Study Description Alfalfa samples from first, second, and third cuttings were collected from four University of Wisconsin Agricultural Research Stations (Arlington, Ashland, Lancaster, and Marshfield) during the 1992 and 1993 growing seasons. Samples consisted of 200 to 300 alfalfa stems collected from weed free portions of fields. Stems were clipped at a height of 1.5 in. from an area approximately 6 by 35 in. The tallest stem from each sample was measured to the nearest 0.25 in. (HEIGHT) and the most mature stem was given the appropriate maturity rating (MATURITY) according to the modified scale shown in Table . Data for HEIGHT and MATURITY were used in the PEAQ to estimate NDF, ADF, and CP concentrations. Samples were shipped to a commercial lab to obtain forage quality estimates using NIRS. Our lab conducted standard procedures to determine actual values of NDF, ADF, and CP. Quality estimates from the PEAQ method and from NIRS were then compared with lab values to determine the accuracy of the two methods. Applied Questions Does the PEAQ method provide accurate preharvest alfalfa quality information? The PEAQ method accurately predicts NDF and ADF concentrations of preharvest first cut alfalfa as indicated by the 1:l relationship and good correlation between PEAQ estimates and observed values. The PEAQ Full scientific article from which this summary was written begins on page 491 of this issue. method provides farmers with a very good estimate of preharvest NDF and ADF concentrations from second and third cut alfalfa. While the relationship between PEAQ estimates and observed values is not as strong for second and third cuttings as it is for first cutting, PEAQ gives excellent fiber information to producers concerned with preharvest alfalfa quality. The CP concentration of alfalfa from any cutting is not accurately estimated using PEAQ. Do we need to use separate equations for alfalfa harvested at different times of the season? Examination of PEAQ estimates from 1992 samples revealed that the original PEAQ equations in Table seemed to work better with first cut than with second or third cut alfalfa. Therefore, we developed two additional equation sets from the original data. One equation set was developed from and used to evaluate first cut alfalfa and a second set of equations was developed from and used to predict quality of second and third cut alfalfa. Both the original and first cut equations accurately estimated ADF concentration in first cut alfalfa. In addition, the original equation accurately estimated NDF composition of first cut samples. Fiber concentration in second and third cut alfalfa was estimated equally well using either the second and third cut or original equation sets. Crude protein was not predicted accurately with any of the equation sets. Based on our results, we recommend that the original equations be used to predict alfalfa fiber values in all cuts. Recommendations We recommend that the original PEAQ be used to estimate preharvest alfalfa NDF and ADF concentration from all cuttings and that PEAQ not be used to estimate CP concentration. The number of samples required for a given area or field has not been studied but it is evident that several samples per field must be used to obtain representative quality information. Producers should consider size, topography, and other conditions that might affect variability of alfalfa within the field when determinipg the number of samples required. The purpose of PEAQ is to allow producers to quickly and economically gather preharvest quality information to be used in harvest management decisions. Decisions influenced by PEAQ could include: deciding whether or not to harvest based on a combination of PEAQ quality estimates and weather forecasts, deciding the order in which to harvest different fields, and deciding where to store harvested alfalfa coming in from the field. An estimate of quality and quantity of alfalfa in storage will also allow a producer to estimate the amount of purchased feed required to obtain a given level of livestock performance. The PEAQ method is meant to be used as a preharvest management tool. Decisions regarding dairy rations should be based on lab or NIRS quality analyses of stored alfalfa. Maturity categories† used to determine numerical value of most mature stem in sample (MATURITY). MATURITY value Stage of maturity 0 Stem length <6 in. 1 Stem length from 6–12 in. 2 Stem length >12 in. 3 1–2 nodes with visible buds 4 > 2 nodes with visible buds 5 1 node with at least one open flower 6 ≥ 2 nodes with an open flower Adapted from Kalu and Fick, 1981. <jats:cap
10