Extended x-ray-absorption fine-structure study of Ag particles isolated in solid argon

P. A. Montano, W. Schulze, B. Tesche, G. K. Shenoy, T. I. Morrison

Physical review. B, Condensed matter · 1984 · 146 citations · 15 references

Concepts

Abstract

Extended x-ray-absorption fine structure was used to determine the nearest-neighbor distance for silver particles isolated in solid argon. The silver particles were produced in the gas phase with the use of the gas-aggregation technique. In this technique the metal atoms are evaporated in an argon atmosphere in the pressure range 0.1-10 Torr; a cooling of the metal atoms takes place through collision with cold gas atoms. The metal aggregates are then transported by the gas stream through an aperture into a liquid-helium cryopump, where most of the gas is condensed. The metal flow rate is monitored by a quartz oscillator. The size of the metal clusters can be selected by changing the argon pressure, density of the metal atom vapors, and geometric configuration of the cell. The size distribution was determined by introducing a sample holder into the molecular beam, sampling an atomic quantity of approximately ${10}^{15}$ atoms/${\mathrm{cm}}^{2}$, and evaluating the corresponding electron micrographs. Particles with average sizes between 25 and 130 \AA{} were studied. A careful analysis of the data was performed with a thin silver foil at 78 K as a standard. No remarkable effects were observed in the near-edge region of the $K$ edge, but there was a noticeable contraction of the nearest-neighbor distance. This contraction can be explained if we assume the presence of surface stresses. There is good agreement between the observed contraction and the calculated values.

References

15