Use of a scanning electron microscope for screening bipolar surface effects

Justin Lipman, W.C. Bruncke, D. Lloyd Crosthwait, K.F. Galloway, R.L. Pease

IEEE Transactions on Nuclear Science · 1974 · 11 citations · 0 references

Concepts

Abstract

A method of screening bipolar transistors for total dose surface effects using a scanning electron microscope (SEM) is described. This screening technique is implemented by irradiation of a selected pattern of dice on each wafer. The electron-induced damage from the SEM is shown to correlate with equivalent total dose irradiations from a Co <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">60</sup> source. It is also shown that the degradation of the selected dice is characteristic of the remaining dice on the wafer.