Journal of Micromechanics and Microengineering · 2009 · 30 citations · 6 references
EngineeringMechanical EngineeringActuatorsMicrofabricationOpticsLens SystemsMembrane EngineeringMembrane FabricationMembrane MechanicsFabricationFocal LengthHot EmbossingLens Focal LengthMembrane ActuatorsMembrane ThicknessShrinkageThickness Distribution
We present the fabrication process of a fluidic membrane lens system with an integrated piezoelectric pumping actuator. The optical unit and the pumping unit are fabricated through casting using a hot embossing machine. Two different systems, one with a homogeneous membrane thickness, and one with an inhomogeneous membrane thickness distribution, are manufactured. The influence of the volume shrinkage of the silicone during curing on the membrane shape and on the focal length is analyzed. The assembled system achieves a focal length between +52.4 mm and −70.9 mm at a piezovoltage of ±40 V. The full-scale response time of the system is below 24 ms.
6
Tunable microfluidic microlenses
Armin Werber, Hans Zappe · Applied Optics · 2005 · 144 citations
Engineering, Biomedical Engineering, Microelectromechanical Systems +14
High-performance fluidic adaptive lenses
Deying Zhang, Nicole Justis, Victor Lien et al. · Applied Optics · 2004 · 58 citations