Fabrication of a fluidic membrane lens system

Jan Draheim, Florian Schneider, Robert Kamberger, C. Mueller, Ulrike Wallrabe

Journal of Micromechanics and Microengineering · 2009 · 30 citations · 6 references

Concepts

Abstract

We present the fabrication process of a fluidic membrane lens system with an integrated piezoelectric pumping actuator. The optical unit and the pumping unit are fabricated through casting using a hot embossing machine. Two different systems, one with a homogeneous membrane thickness, and one with an inhomogeneous membrane thickness distribution, are manufactured. The influence of the volume shrinkage of the silicone during curing on the membrane shape and on the focal length is analyzed. The assembled system achieves a focal length between +52.4 mm and −70.9 mm at a piezovoltage of ±40 V. The full-scale response time of the system is below 24 ms.

References

6