Applied Optics · 2005 · 144 citations · 7 references
EngineeringBiomedical EngineeringMicroelectromechanical SystemsMicrofabricationPhotonicsMicrofluidic Device FabricationMicrofluidic DevicesMicrofluidic SystemsMicrofluidicsFocal LengthLens DesignLens Focal LengthLiquid Flow HandlingMicro-lens ArraysMicrofluidic FabricationMicrofluidic MaterialsSilicon
A novel type of liquid microlens, bounded by a microfabricated, distensible membrane and activated by a microfluidic liquid-handling system, is presented. By use of an elastomer membrane fabricated by spin coating onto a dry-etched silicon substrate, the liquid-filled cavity acts as a lens whereby applied pressure changes the membrane distension and thus the focal length. Both plano-convex and plano-concave lenses, individual elements as well as arrays, were fabricated and tested. The lens surface roughness was seen to be approximately 9 nm rms, and the focal length could be tuned from 1 to 18 mm. This lens represents a robust, self-contained tunable optical structure suitable for use in, for example, a medical environment.
7
Tom N. Krupenkin, Shu Yang, P. Mach · Applied Physics Letters · 2003 · 318 citations
Natural Sciences, Materials Engineering, Materials Science +11
Variable-focusing microlens with microfluidic chip
Jackie Chen, Weisong Wang, Ji Fang et al. · Journal of Micromechanics and Microengineering · 2004 · 189 citations
Engineering, Materials Engineering, Mechanical Engineering +17