Applied Physics Letters · 1995 · 13 citations · 0 references
EngineeringElectrical EngineeringPhysicsElectronic MaterialsOptoelectronicsSemiconductor DevicesDevice CharacterizationEtching ProcessesMaterial Degradation AssessmentSemiconductor DefectsSemiconductor Device MaterialsSemiconductor ReliabilityDamping MeasurementDry EtchingEtch DamageEtchingIon Beam EtchingLattice DamagePlasma EtchingReactive Ion Etching
The crystal damage in optoelectronic devices caused by dry etching methods [ion beam etching, reactive ion etching, etching with plasmas excited by electron cyclotron resonance (ECR)] was evaluated. The analytics applied are photoluminescence and Fabry-Perot damping measurement which were applied to waveguides. A significant improvement is observed using ECR etching as low damage combined with high etching rates is concerned. To evaluate a method as soft or hard etching, Fabry-Perot damping measurement has emerged to be the most discriminate and decisive tool.