Effect of Dissolved Oxygen on Cu Corrosion in Single Wafer Cleaning Process

M. Imai, Yukinari Yamashita, T. Futatsuki, Morio Shiohara, Seiichi Kondo, Shuichi Saito

Japanese Journal of Applied Physics · 2009 · 10 citations · 1 references

Concepts

Abstract

We investigated Cu corrosion at the via bottom of multi-layered Cu interconnects that occurred after post-etching wet cleaning and caused via open failures. We found that oxygen was dissolved into de-ionized water (DIW) on the wafer edge from the air atmosphere during the rinse step after chemical cleaning and that Cu was oxidized due to the high oxidation-reduction potential (ORP) of the rinse DIW. To prevent Cu interconnects from being corroded, control of the dissolved oxygen and the ORP of the rinse DIW by decreasing the oxygen concentration of the atmosphere in the cleaning machine as well as by using H2 water is required. This will become indispensable in the cleaning process of the next generation Cu interconnects.

References

1