Electronics Letters · 1999 · 83 citations · 3 references
EngineeringElectrical EngineeringMicroelectromechanical SystemsMicroelectronicsMicrowave EngineeringMems DesignMems FabricationMems SwitchesMicrowave Integrated CircuitsMicrowave Semiconductor DevicesRf MemsInsertion LossIsolationMicromachined Switch DesignMicroswitchesMicrowave SwitchesResponse TimeRf Mems SwitchesRobustness
A MEMS switch has been developed for microwave applications. The switch has an actuation of 30 V, a response time of 20 µs, and mechanical robustness to withstand 109 actuations. An RF performance with >50 dB isolation below 2 GHz and <0.2 dB insertion loss from DC to 40 GHz has been measured.