Applied Optics · 2013 · 14 citations · 14 references
Natural SciencesPhysicsMetrologyOptical MaterialsOpticsDisplacement MeasurementFiber OpticsInterferometryOptical FibersOptical MetrologyRefractive IndexDisplacementExit PupilFiber Optic InterferometryIndex Of Refraction MeasurementInterferometric MeasurementInterferometric Refractive Index MeasurementOptical Displacement MeasurementRefractive Index Measurement
A refractive index measurement method by measuring the longitudinal displacement of a point light source (PLS) after passing through a plane-parallel-plate sample is proposed. The displacement is derived by applying two point-diffraction longitudinal shearing interferometric measurements if the distance from the PLS to the exit pupil is predetermined. With two fibers to simulate the ideal PLS, an experimental system for solid and liquid sample tests is proposed to verify the principle. The experimental results indicate that its accuracy is in the order of 10(-4). Ways to improve the accuracy are discussed based on the detailed error analysis.
14
Craig M. Herzinger, Blaine Johs, William A. McGahan et al. · Journal of Applied Physics · 1998 · 1.1K citations
Natural Sciences, Materials Engineering, Materials Science +17
Measurement of Thin Film Parameters with a Prism Coupler
R. Ulrich, R. Torge · Applied Optics · 1973 · 955 citations
Refractive Index Measurement and its Applications
Shyam Singh · Physica Scripta · 2002 · 266 citations
Natural Sciences, Materials Engineering, Materials Science +11