Chemical Contamination Sensor for Phosphate Ester Hydraulic Fluids

Sumit Paul, W. Legner, Angelika Krenkow, Gerhard Müller, Thierry Lemettais, Francois Pradat, Delphine Hertens

International Journal of Aerospace Engineering · 2010 · 21 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

The paper deals with chemical contamination monitoring in phosphate-ester-based hydraulic fluids using nondispersive infrared (NDIR) optical absorption. Our results show that NDIR monitoring allows detecting the take-up of water into such fluids and their hydrolytic disintegration as these become additionally stressed by Joule heating. Observations on the O–H stretching vibration band (3200–3800 ) are used for determining the free water content (0–1.5%) and the Total Acid Number (0–1 mgKOH/g). Both quantities can be assessed by monitoring the strength and the asymmetry of the O–H vibration band with regard to the free water absorption band centred around 3500 . As such optical parameters can be assessed without taking fluid samples from a pressurised hydraulic system, fluid degradation trends can be established based on regular measurements, before irreversible damage to the fluid has occurred. Therefore maintenance actions can be planned accordingly, which is very important for the airline, as unscheduled maintenance disturbs the flights organisation and often generates money loss.

References

5