Review of Scientific Instruments · 1992 · 13 citations · 4 references
Natural SciencesNuclear EngineeringInstrumentationPlasma PhysicsRadiation PhysicsCharged Particle DetectionDetector SystemsDetector TechnologyRadiation DetectorsUltraviolet DetectorsUltraviolet InstrumentationAcceleratorsBeam InstrumentationDegradationDiagnostic Device DesignIon Beam DiagnosticsMicrochannel Plate DetectorsMicrochannel PlatesVacuum Systems
Ordinary gas ionization profile monitors, in common use at high-energy accelerators, are not useful in low density gases. Modern accelerators usually have high quality vacuum systems that maintain pressures below 10−8 Torr. We will describe a beam profile monitor that not only operates in the range of 10−11 Torr, but is noninvasive. Shaped electric fields sweep beam-generated ions out of a collection area onto the input face of a detector. The detector uses a dual microchannel plate to generate a gain of approximately 107 electrons per ion. An ultraviolet lamp provides a signal for monitoring the eventual degradation of the microchannel plate. The complete device contains a horizontal detector, a vertical detector, and a set of electrodes to nullify first-order electrostatic effects on the particle beam. Recent results from the initial use of the profile monitor are quite promising and demonstrate a new range of operation for this type of beam diagnostic device.
4
Penetration of Protons, Alpha Particles, and Mesons
U. Fano · Annual Review of Nuclear Science · 1963 · 1.1K citations