Journal of Applied Physics · 1983 · 64 citations · 11 references
Natural SciencesMaterials SciencePhysicsElectronic MaterialsPlasma PhysicsSemiconductor DevicesHigh-temperature PlasmasPlasma DiagnosticsPlasma Surface TreatmentPlasma-surface InteractionsJunction CapacitanceLow-pressure Plasma TreatmentPlasma Exposure EffectsPlasma TreatmentPlasma-induced DamagePlasma-induced Surface DamageSilicon
The neutralization of deep-level centers associated with palladium and platinum in silicon after exposure to a low-pressure hydrogen plasma has been observed using transient junction-capacitance spectroscopy. In n-type silicon, a palladium-related level at Ec −0.22 eV and platinum-related level at Ec −0.28 eV were neutralized by a low-temperature (300 °C) plasma treatment. In p-type silicon, a palladium-related level at Ev +0.32 eV was also neutralized by this treatment, but a platinum-related level at Ev +0.33 eV was unaffected by hydrogen plasma exposure. Possible mechanisms for the observed reduction in defect electrical activity are discussed.
11
Complex nature of gold-related deep levels in silicon
D. V. Lang, H. G. Grimmeiss, Evert Jan Meijer et al. · Physical review. B, Condensed matter · 1980 · 235 citations
J. W. Chen, A. G. Milnes · Annual Review of Materials Science · 1980 · 219 citations
Natural Sciences, Materials Engineering, Materials Science +12