Life SciencesMicrobiologyBacteriologyFood MicrobiologyPlasma PhysicsEnvironmental CleaningEnvironmental DisinfectionEquipment SterilizationSterile ProcessingSterilization TechniquesBacillus SubtilisLog Reduction AssessmentLog Reduction ValuePlasma DecontaminationPlasma SterilizationPolyethylene TerephthalatePolyethylene Terephthalate BottlesSpore Reduction
A pulsed power supply was used to generate a corona discharge on a polyethylene terephthalate bottle, to conduct plasma sterilization at atmospheric pressure. Before generating such a discharge, minute quantities of water were attached to the inner surface of the bottle and to the surface of a high voltage (HV) electrode inserted into the bottle. Next, high-voltage pulses of electricity were discharged between electrodes for 6.0s, while rotating the bottle. The resulting spore log reduction values of Bacillus subtilis and Aspergillus niger on the inner surface of the bottle were 5.5 and 6 or higher, respectively, and those on the HV electrode surface were each 6 or higher for both strains. The presence of the by-products gaseous ozone, hydrogen peroxide, and nitric ions resulting from the electrical discharge was confirmed.