Electrical EngineeringTotal Ionizing DoseHealth SciencesMedicineRadiation ExposureLm124 Operational AmplifierSingle Event EffectsCosmic RayFlash X-ray FacilityRadiation ImagingOperational AmplifierDosimetryRadiologyRadiation Protection
The Synergistic effect between Total Ionizing Dose (TID) and Analog Transient Radiation Effects in Electronics (ATREE) in an operational amplifier (LM124) is investigated. A predictive methodology, based on a previously developed ATREEs simulation tool, is used to model the synergistic phenomena. This phenomenon is simulated for the first time and the duration of the ATREEs' is found to be identical to those measured experimentally. ATREEs induced by high dose-rate X-ray pulses are investigated using a flash X-ray facility. The ATREEs induced in the LM124 operational amplifier configured in three different bias configurations are investigated and simulated.