Discharge conditions for CW and pulse-modulated surface-wave plasmas in low-temperature sterilization

Lei Xu, Fumie Terashita, H Nonaka, Akihisa Ogino, Toshi Nagata, Yukio Koide, S Nanko, I Kurawaki, Masaaki Nagatsu

Journal of Physics D Applied Physics · 2005 · 13 citations · 16 references

Concepts

Abstract

The discharge conditions required for low-temperature plasma sterilization were investigated using low-pressure surface-wave plasma (SWP). The discharge conditions for both continuous wave (CW) and pulse-modulated SWPs in low-temperature sterilization of Geobacillus stearothermophilus with a population of 1.5 × 106 and 3.0 × 106 were studied by varying the microwave input power from 500 W to 3 kW, and the effective plasma treatment time from 40 to 300 s. Results showed that sterilization was possible in a shorter treatment time using a higher microwave power for both CW and pulse-modulated SWPs. Pulse-modulated SWPs gave effective sterilization at a temperature roughly 10 to 20 °C below that of CW SWPs under the same average microwave power.

References

16