LIQUID‐TO‐PARTICLE HEAT TRANSFER DURING CONTINUOUS TUBE FLOW: INFLUENCE of FLOW RATE and PARTICLE to TUBE DIAMETER RATIO<sup>1</sup>

Sudhir K. Sastry, Marybeth Lima, J. BRIM, T. BRUNN, Brian Heskitt

Journal of Food Process Engineering · 1990 · 47 citations · 12 references

Concepts

Abstract

ABSTRACT Liquid‐to‐particle convective heat transfer coefficients were measured during continuous flow through tubes, using an experimental technique in which a thermocouple was moved at the same speed as the particle. Water was used as the carrier fluid and transducer particles were made hollow to approximate densities of real food particles. Results from over 250 experimental runs over a fluid Reynolds number range from 7300 to 43600, showed that the convective coefficient was increased significantly with increasing fluid flow rate and particle to tube diameter ratio. Convective coefficient values ranged from 688 to 3005 w/m 20 C depending on the experimental conditions. Dimensionless correlations obtained between the Nusselt number, particle Reynolds number, particle to tube diameter ratio, and the particle Froude number yielded R 2 values ranging from 0.82 to 0.92 depending on the complexity of the relation.

References

12