PLoS ONE · 2012 · 55 citations · 18 references
MedicineNeurologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingCerebrovascular DiseaseMagnetic Resonance ImagingMedical ImagingStrokeStroke ImagingAcute Stroke ImagingCerebral Ischemia AssessmentNeuroimaging Of Ischemic StrokeStroke NeuroimagingStructural MriT1-weighted ImagingT2-weighted ImagingUltra-high-field Magnetic Resonance Imaging
INTRODUCTION: Magnetic resonance imaging (MRI) using field strengths up to 3 Tesla (T) has proven to be a powerful tool for stroke diagnosis. Recently, ultrahigh-field (UHF) MRI at 7 T has shown relevant diagnostic benefits in imaging of neurological diseases, but its value for stroke imaging has not been investigated yet. We present the first evaluation of a clinically feasible stroke imaging protocol at 7 T. For comparison an established stroke imaging protocol was applied at 3 T. METHODS: In a prospective imaging study seven patients with subacute and chronic stroke were included. Imaging at 3 T was immediately followed by 7 T imaging. Both protocols included T1-weighted 3D Magnetization-Prepared Rapid-Acquired Gradient-Echo (3D-MPRAGE), T2-weighted 2D Fluid Attenuated Inversion Recovery (2D-FLAIR), T2-weighted 2D Fluid Attenuated Inversion Recovery (2D-T2-TSE), T2* weighted 2D Fast Low Angle Shot Gradient Echo (2D-HemoFLASH) and 3D Time-of-Flight angiography (3D-TOF). RESULTS: The diagnostic information relevant for clinical stroke imaging obtained at 3 T was equally available at 7 T. Higher spatial resolution at 7 T revealed more anatomical details precisely depicting ischemic lesions and periinfarct alterations. A clear benefit in anatomical resolution was also demonstrated for vessel imaging at 7 T. RF power deposition constraints induced scan time prolongation and reduced brain coverage for 2D-FLAIR, 2D-T2-TSE and 3D-TOF at 7 T versus 3 T. CONCLUSIONS: The potential of 7 T MRI for human stroke imaging is shown. Our pilot study encourages a further evaluation of the diagnostic benefit of stroke imaging at 7 T in a larger study.
18
Ultra-high-field imaging distinguishes MS lesions from asymptomatic white matter lesions
Emma Tallantyre, Jennifer Dixon, Ian Donaldson et al. · Neurology · 2011 · 217 citations · Full text
Seven‐tesla magnetic resonance images of the substantia nigra in Parkinson disease
Dae‐Hyuk Kwon, Jong‐Min Kim, Se‐Hong Oh et al. · Annals of Neurology · 2011 · 195 citations
Medicine, Neuroscience, Radiology +17
Jürgen Hennig, Klaus Scheffler · Magnetic Resonance in Medicine · 2001 · 195 citations · Full text