Standoff detection of explosives with broad band tunable external cavity quantum cascade lasers

F. Fuchs, Stefan Hugger, Michel Kinzer, Quankui Yang, W. Bronner, R. Aidam, Kai Degreif, Sven Rademacher, Frank Schnürer, Wenka Schweikert

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2011 · 10 citations · 0 references

Concepts

Abstract

We present standoff detection of various explosives by backscattering spectroscopy, using a sensing system based on mid-IR external-cavity quantum cascade lasers (EC-QCL) with a broad tunable range of about 300 cm<sup>-1</sup>. Traces of TNT (trinitrotoluene), PETN (pentaerythritol tetranitrate) and RDX (cyclotrimethylenetrinitramine) as well as different nonhazardous substances were investigated by illuminating them with the EC-QC laser and collecting the diffusely backscattered light. Tuning the EC-QCL across the characteristic absorption spectra enables us to detect and identify the explosives against a background of non-hazardous materials.