Breast Cancer Detection Using Si-Doped MoS<sub>2</sub> Channel-Based Thickness Engineered TFET Biosensor

Priya Kaushal, Gargi Khanna

IEEE Sensors Letters · 2024 · 22 citations · 20 references

Concepts

Abstract

This letter investigates the electrical performance characteristics for breast cancer cell line detection by developing the Si-doped molybdenum disulfide thickness engineered tunnel field effect transistor biosensor. A complete study of the electrostatic field is presented, including the surface potential, electric field, transconductance (g<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub>), threshold voltage (V<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sub>), <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> current (I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ON</sub>), and subthreshold swing. The sensitivity is analyzed in terms of drain current (I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ds</sub>), g<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub>, V<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sub>, I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ON</sub>, I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ON</sub>/I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">OFF</sub> ratio, and g<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub>. Further, this study investigates the impact of device geometry variations, specifically cavity thickness, and length on the sensitivity of drain current (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{S}_{\rm{I}_{\rm{ds}}}$</tex-math></inline-formula>), transconductance (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{S}_{\rm{g}_{\rm{m}}}$</tex-math></inline-formula> ), threshold voltage (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text{S}}_{{{\rm{V}}_{{\rm{th}}}}}$</tex-math></inline-formula>), and <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> current (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text{S}}_{{{\rm{I}}_{{\rm{ON}}}}}$</tex-math></inline-formula>). In addition, the impact of immobilized cell line occupancy on device performance has been examined. The presented biosensor is highly sensitive with increased cavity occupancy resulting in enhanced performance. As a result, array-based screening and diagnosis of breast cancer cells can be accomplished with the device, which is also economical and simpler to fabricate.

References

20