IEEE Sensors Letters · 2024 · 22 citations · 20 references
EngineeringBiomedical EngineeringElectrical EngineeringBiosensorsMicroelectronicsSemiconductor DevicesBioelectronic MedicineBiological SensorsBiomedical SensorsBiosensor DesignMetal-oxide-semiconductor Field-effect TransistorsThin-film TransistorsBiosensor MaterialsElectrostatic Field StrengthElectrostatic Surface PotentialField-effect Transistor BiosensorsField-effect Transistor Transfer CharacteristicsLine DetectionSurface PotentialThreshold Voltage
This letter investigates the electrical performance characteristics for breast cancer cell line detection by developing the Si-doped molybdenum disulfide thickness engineered tunnel field effect transistor biosensor. A complete study of the electrostatic field is presented, including the surface potential, electric field, transconductance (g<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub>), threshold voltage (V<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sub>), <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> current (I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ON</sub>), and subthreshold swing. The sensitivity is analyzed in terms of drain current (I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ds</sub>), g<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub>, V<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sub>, I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ON</sub>, I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ON</sub>/I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">OFF</sub> ratio, and g<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub>. Further, this study investigates the impact of device geometry variations, specifically cavity thickness, and length on the sensitivity of drain current (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{S}_{\rm{I}_{\rm{ds}}}$</tex-math></inline-formula>), transconductance (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{S}_{\rm{g}_{\rm{m}}}$</tex-math></inline-formula> ), threshold voltage (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text{S}}_{{{\rm{V}}_{{\rm{th}}}}}$</tex-math></inline-formula>), and <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> current (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text{S}}_{{{\rm{I}}_{{\rm{ON}}}}}$</tex-math></inline-formula>). In addition, the impact of immobilized cell line occupancy on device performance has been examined. The presented biosensor is highly sensitive with increased cavity occupancy resulting in enhanced performance. As a result, array-based screening and diagnosis of breast cancer cells can be accomplished with the device, which is also economical and simpler to fabricate.
20
Mousa Hussein, Falah Awwad, Dwija Jithin et al. · Scientific Reports · 2019 · 109 citations · Full text
Natural Sciences, Biomedical Engineering, Electrical Engineering +17