Depression and Anxiety · 2024 · 11 citations · 44 references
MedicineNeurosciencePsychiatryBiomedical ImagingBiomedical Signal ProcessingComputational NeuroscienceBrain ImagingComputer-aided DiagnosisDeep LearningFunctional NeuroimagingInfrared SpectroscopyNear-infrared SpectroscopyConvolutional Neural NetworksDeep Learning DiagnosticsDeep Learning-based DiagnosisFunctional Near-infrared SpectroscopyMajor Depressive Disorder DiagnosisNear-infrared Spectroscopy AssessmentStroop Task PerformanceStroop Test
Background: Functional near-infrared spectroscopy (fNIRS) is being extensively explored as a potential primary screening tool for major depressive disorder (MDD) because of its portability, cost-effectiveness, and low susceptibility to motion artifacts. However, the fNIRS-based computer-aided diagnosis (CAD) of MDD using deep learning methods has rarely been studied. In this study, we propose a novel deep learning framework based on a convolutional neural network (CNN) for the fNIRS-based CAD of MDD with high accuracy. Materials and Methods: The fNIRS data of participants-48 patients with MDD and 68 healthy controls (HCs)-were obtained while they performed a Stroop task. The hemodynamic responses calculated from the preprocessed fNIRS data were used as inputs to the proposed CNN model with an ensemble CNN architecture, comprising three 1D depth-wise convolutional layers specifically designed to reflect interhemispheric asymmetry in hemodynamic responses between patients with MDD and HCs, which is known to be a distinct characteristic in previous MDD studies. The performance of the proposed model was evaluated using a leave-one-subject-out cross-validation strategy and compared with those of conventional machine learning and CNN models. Results: The proposed model exhibited a high accuracy, sensitivity, and specificity of 84.48%, 83.33%, and 85.29%, respectively. The accuracies of conventional machine learning algorithms-shrinkage linear discriminator analysis, regularized support vector machine, EEGNet, and ShallowConvNet-were 73.28%, 74.14%, 62.93%, and 62.07%, respectively. Conclusions: In conclusion, the proposed deep learning model can differentiate between the patients with MDD and HCs more accurately than the conventional models, demonstrating its applicability in fNIRS-based CAD systems.
44
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Ramprasaath R. Selvaraju, Michael Cogswell, Abhishek Das et al. · 2017 · 21.6K citations
Theo Vos, Amanuel Alemu Abajobir, Kalkidan Hassen Abate et al. · The Lancet · 2017 · 13.5K citations · Full text