Biomedical Signal Processing and Control · 2024 · 13 citations · 29 references
EngineeringBioengineeringBiomedical EngineeringBioenergeticsBioinstrumentationPhysiological Systems ModelingCardiac PhysiologyCardiac Signal ProcessingCardiovascular BiomechanicsCardiovascular PhysiologyAvailable EnergyCardiac Energy ConservationCardiac MechanicsEnergy HarvestingPower AvailableSignal Processing Acceleration
Accurately estimating the complex motion of the heart can unlock enormous potential for kinetic energy harvesting. This paper presents a foundational dataset for heart kinetic motion through in-vivo tests and investigates the most influential factors in heart kinetic motion. In-vivo tests on a living pig's heart, with signal processing, were carried out to study the heart movement by heart beating and respiration motions. A network of nine points on the heart was employed for in vivo measurements. These measurements illustrated the kinetic energy signals in displacement, velocity, and acceleration. The results indicated that the motion level varies in distinct locations over epicardium. The statistical features and autocorrelations were reported for these points, illustrating the highest displacement and acceleration. Each heartbeat generated an energy of 14.35 mJ and a power of 1.03 W. However, this available energy is not uniformly distributed. The results illustrated that not only is cardiac movement location-dependent, but the speed of cardiac displacement cycles is also location-dependent. The right atrium has the highest cardiac kinetic movement with an amplitude of 16.19 mm displacement and 16.3 m/s2 acceleration. To evaluate the energy harvesting possibility from the heart's motion, a piezoelectric energy harvester was simulated by the finite element method, implying that the energy harvesting level significantly depends on implant location over epicardium. The results of this study open the potential of designing novel energy harvesters based on accurate heart movements and provide a foundation for future investigations of energy harvesting for leadless pacemaker energy systems.
29
Anatomy of the pig heart: comparisons with normal human cardiac structure
SIMON J. CRICK, Mary N. Sheppard, Siew Yen Ho et al. · Journal of Anatomy · 1998 · 460 citations · Full text
Life Sciences, Anatomy, Physiology +16
Biodegradable Piezoelectric Force Sensor
Eli Curry, Kai Ke, Meysam T. Chorsi et al. · Proceedings of the National Academy of Sciences · 2018 · 417 citations