Cellular & Molecular Biology Letters · 2024 · 55 citations · 42 references
MedicineMolecular BiologyMolecular GeneticsCancer ScreeningDiagnostic MicrobiologyVirologyCancer Molecular DiagnosticsCervical CancerCervical CytologyCrispr-cas SystemsNucleic Acid Amplification TestingPolymerase Chain ReactionCervical Cancer ScreeningHigh-risk Human Papillomavirus TypesHpv ScreeningMolecular Point-of-care TestingMultiplex Amplification AssaysMultiplex Polymerase Chain Reaction (Pcr)Multiplex Polymerase Chain Reaction AssaysRecombinase Polymerase Amplification
Persistent infection with high-risk human papillomavirus (HR-HPV) is the primary and initiating factor for cervical cancer. With over 200 identified HPV types, including 14 high-risk types that integrate into the host cervical epithelial cell DNA, early determination of HPV infection type is crucial for effective risk stratification and management. Presently, on-site immediate testing during the HPV screening stage, known as Point of Care Testing (POCT), remains immature, severely limiting the scope and scenarios of HPV screening. This study, guided by the genomic sequence patterns of HPV, established a multiplex recombinase polymerase amplification (RPA) technology based on the concept of "universal primers." This approach achieved the multiple amplification of RPA, coupled with the CRISPR/Cas12a system serving as a medium for signal amplification and conversion. The study successfully constructed a POCT combined detection system, denoted as H-MRC12a (HPV-Multiple RPA-CRISPR/Cas12a), and applied it to high-risk HPV typing detection. The system accomplished the typing detection of six high-risk HPV types (16, 18, 31, 33, 35, and 45) can be completed within 40 min, and the entire process, from sample loading to result interpretation, can be accomplished within 45 min, with a detection depth reaching 1 copy/μL for each high-risk type. Validation of the H-MRC12a detection system's reproducibility and specificity was further conducted through QPCR on 34 clinical samples. Additionally, this study explored and optimized the multiplex RPA amplification system and CRISPR system at the molecular mechanism level. Furthermore, the primer design strategy developed in this study offers the potential to enhance the throughput of H-MRC12a detection while ensuring sensitivity, providing a novel research avenue for high-throughput detection in Point-of-Care molecular pathogen studies.
42
CRISPR-Cas12a target binding unleashes indiscriminate single-stranded DNase activity
Janice S. Chen, Enbo Ma, Lucas B. Harrington et al. · Science · 2018 · 4.4K citations
Nucleic acid detection with CRISPR-Cas13a/C2c2
Jonathan S. Gootenberg, Omar O. Abudayyeh, Jeong Wook Lee et al. · Science · 2017 · 3.8K citations · Full text
Multiplexed and portable nucleic acid detection platform with Cas13, Cas12a, and Csm6
Jonathan S. Gootenberg, Omar O. Abudayyeh, Max J. Kellner et al. · Science · 2018 · 2.6K citations · Full text
DNA Detection Using Recombination Proteins
Olaf Piepenburg, Colin H. Williams, Derek L. Stemple et al. · PLoS Biology · 2006 · 2.5K citations · Full text
CRISPR-Cas12a-assisted nucleic acid detection
Shiyuan Li, Qiuxiang Cheng, Jing-Man Wang et al. · Cell Discovery · 2018 · 1.5K citations · Full text