ACM Transactions on Sensor Networks · 2023 · 17 citations · 43 references
EngineeringBiomedical EngineeringElectrical EngineeringBiomedical Signal ProcessingSensorsWireless CommunicationsMobile SensingNoiseRespiratory MonitoringRespiratory Signal AnalysisSensor NetworksWireless NetworksDenoisingNoise CharacteristicsRespiratory Rate EstimationRespiratory Signal DenoisingSensingSignal DenoisingWi-fi SensingWireless Sensing
Recent years have witnessed the emerging development of single-antenna wireless respiration detection that can be integrated into IoT devices with a single transceiver chain. However, existing single-antenna-based solutions are all limited by the short sensing range within 2-4 m due to noise interference, which makes them difficult to be adopted in most room-scale scenarios. To deal with this dilemma, we propose a room-scale, noise-resistance, and accurate respiration monitoring system, named Wi-Cyclops , 1 which captures CSI changes induced by respiratory movements only via one antenna on commercial WiFi devices. To push the limits of effective sensing distance, we innovatively supply a new perspective to review the CSI samples along the sub-carrier dimension. From this dimension, we find that the interrelationship between sub-carriers with different timestamps still shows a high correlation even though the SNR decreases. Based on that, we analyze the noise characteristics along the sub-carrier dimension and correspondingly design a series of denoising schemes. Specifically, we carefully design a PCA-based denoising method to filter out ambient noises. After that, considering the low distribution densities of the AGC-induced noise, we then remove it by optimizing the DBSCAN denoising method with the K-Means-based adaptive radius search. Extensive experiments demonstrate that our system can work effectively in three typical family scenarios. Wi-Cyclops can achieve 98% accuracy even when the person is 7 m away from the transceiver pair. Compared with the start-of-art single-antenna-based approaches in real scenarios, Wi-Cyclops can improve the sensing range from 3 m to 7 m, which can meet the requirements of room-scale respiration monitoring. Additionally, to show the high compatibility with smart home devices, Wi-Cyclops is deployed on seven commercial IoT devices and still achieves a low average absolute error with 0.41 bpm.
43
Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China
Chaolin Huang, Yeming Wang, Xingwang Li et al. · The Lancet · 2020 · 51.8K citations · Full text
Daniel Halperin, Wenjun Hu, Anmol Sheth et al. · ACM SIGCOMM Computer Communication Review · 2011 · 1.7K citations
Engineering, Computer Engineering, Electrical Engineering +15
Understanding and Modeling of WiFi Signal Based Human Activity Recognition
Wei Wang, Alex X. Liu, Muhammad Shahzad et al. · 2015 · 1.1K citations
Smart Homes that Monitor Breathing and Heart Rate
Fadel Adib, Hongzi Mao, Zachary Kabelac et al. · 2015 · 892 citations · Full text