Micro-Electro-Mechanical Systems (MEMS) · 1996 · 10 citations · 0 references
Natural SciencesMaterials EngineeringMaterials ScienceMaterials CharacterizationMechanical Behavior Of MaterialsThin FilmsFracture MechanicsSilicon MaterialsStrain AnalysisStrength Of MaterialsStress-strain BehaviorThin Film StrainBrittle Fracture BehaviorCantilever MechanicsFracture TestingMechanical Strength TestingMicromechanical Fracture AnalysisMicromechanical TestingPolycrystalline SiliconThin Film Failure Mechanisms
Abstract A new structure for determining the fracture characteristics of brittle thin films has been designed, fabricated and tested. The structure consists of a rigid central shuttle to which are attached a number of cantilever beams of varying lengths which will provide the desired fracture information. The central shuttle is tethered to the substrate by flexible beams which allow it to be moved controllably in one direction while the free ends of the cantilevers are prevented from movement by stops. By measuring the shuttle displacement at which the various beams fail, the failure strain of the beam material is determined. This structure design has been used to examine the fracture characteristics of a particular LPCVD polycrystalline silicon film, and the degradation in strength which occurs with exposure to hydrofluoric acid. The average strain at fracture measured for this heavily phosphorus doped polycrystalline silicon was 1.1% for a 10 minute exposure to hydrofluoric acid. This value drops to 0.84% after the material is exposed to hydrofluoric acid for 2 hours.