Journal of Vascular and Interventional Radiology · 2023 · 18 citations · 15 references
MedicineSurgeryDialysisHemodialysisVascular SurgeryBalloon AngioplastyDialysis AccessDialysis Access InterventionsDialysis Vascular AccessFistula ManagementVascular AccessAccess Circuit RecanalizationAccess Dysfunction EvaluationSerious Adverse EventsTarget Lesion RevascularizationVascular Access DysfunctionVascular Access EvaluationVascular Access PatencyVascular Access Thrombosis
PURPOSE: To present the 36-month outcomes of the prospective randomized IN.PACT AV Access study of participants with obstructive de novo or restenotic native upper extremity arteriovenous dialysis fistula lesions treated with drug-coated balloon (DCBs) or standard percutaneous transluminal angioplasty (PTA) following successful high-pressure PTA. MATERIALS AND METHODS: Participants at 29 international sites were randomized 1:1 to receive an IN.PACT AV DCB (n = 170) or undergo PTA (n = 160). The outcomes through 36 months included target lesion primary patency (TLPP) and access circuit primary patency (ACPP) (composites of clinically driven target lesion or access circuit revascularization and/or access circuit thrombosis), number of reinterventions, and serious adverse events involving the access circuit. RESULTS: TLPP was 52.1% in the DCB group compared with 36.7% in the PTA group through 24 months and 43.1% in the DCB group compared with 28.6% in the PTA group through 36 months (both log-rank P < .001). ACPP was 39.4% in the DCB group compared with 25.3% in the PTA group through 24 months and 26.4% in the DCB group compared with 16.6% in the PTA group through 36 months (both log-rank P < .001). Cumulative incidence of access circuit thrombosis through 36 months was 8.2% in the DCB group compared with 18.3% in the PTA group (log-rank P = .040). Cumulative incidence of mortality through 36 months was 26.6% in the DCB group compared with 30.8% in the PTA group (log-rank P = .71). CONCLUSIONS: This study demonstrated superior TLPP and ACPP with DCBs compared with PTA, with no difference in mortality through 3 years. Access circuit thrombosis was statistically significantly higher in the PTA group at 3 years.
15
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Charmaine E. Lok, Thomas S. Huber, Timmy Lee et al. · American Journal of Kidney Diseases · 2020 · 2.4K citations
Drug-Coated Balloons for Dysfunctional Dialysis Arteriovenous Fistulas
R. Lookstein, Hiroaki Haruguchi, Kenneth Ouriel et al. · New England Journal of Medicine · 2020 · 214 citations · Full text
Scott O. Trerotola, Theodore F. Saad, Prabir Roy‐Chaudhury · Journal of Vascular and Interventional Radiology · 2019 · 110 citations · Full text
Medicine, Nephrology, Surgery +8